10
ENGINEER ACCESS CODE 1-1
The engineer access code is programmed to 7890 by default. To change
this code (while in engineering mode):
1. Enter 1-1. LEDs 1, 2, 3 and 4 will illuminate.
2. Enter the new 4 digit code. After each keypress one LED will go out.
The speaker will emit an accept tone if the new code is accepted.
If the speaker emits an error tone, then your new chosen code is invalid.
This could be due to a conflict with another code. At this time your old
access code is still valid. Repeat the procedure using a different code.
ENGINEER EVENT LOG REVIEW 5 (Choices of set & unset)
The Panel stores the last set and unset states and the last alarm event. The
log is arranged into SET and UNSET events. Log entries indicate the first
and subsequent alarms and also isolated circuits. First to alarm is shown
by the LED being ON continuously. Subsequent alarms are shown by the
LED(s) flashing and isolated circuits by the LED(s) pulsing slowly. The
buzzer sounds whilst reviewing the SET logs and is silent while reviewing
the UNSET logs.
To view the engineers log press the 5 key from the program mode. The log
starts viewing DAY 1 SET. View the remaining logs by pressing the
relevant key 2 for 2
nd
, 3 for 3
rd
and so on up to 9. Press the 0 key to get the
last alarm condition.
The # key alternates between SET and UNSET logs and can be used at
any time.
ENGINEER TEST OPTIONS 6 (Range 0-5)
To conduct testing activities first press the 6 key from within engineering
mode and then one of the option below.
Enter 0 Internal buzzer ( entry exit sound etc. )
Enter 1 Internal Sounder ( Alarm sounds from speaker / keypad )
Enter 2 External Sounder
Enter 3 External Strobe
Enter 4 L+ Terminal( even if programmed as ID- )
Enter 5 FULL LOAD ( Everything enabled )
ACCESS CODE
ENGINEER
LOG REVIEW
ENGINEER
TEST OPTIONS